PRODUCTS
pl|en|hu
REDWALL IP
SIP-3020-IP SIP-4010-IP
SIP-404-IP
Medium Range
Synthesized Intelligent PIR
with IP communication and PoE power supply

The SIP-3020-IP, SIP-4010-IP, and SIP-404-IP detectors in the REDWALL-V Series
are designed for use in small and mid-sized outdoor areas. They have an intelligent
detection system that uses data on the ambient environment, such as temperature
and illuminance conditions, to automatically adjust the sensitivity.

Mechanisms for easy installation enable accurate adjustment of the detection area at setup,
which results in more reliable operation. The optional AVF-1 Area View Finder allows
the installer to visually identify the detection area.

The detectors are also equipped with anti-rotation and anti-masking. They can also detect
vandalism or tampering on the units. These functions provide greater security in operations.

Detectors in the REDWALL-V Series are ideal for triggering outdoor camera systems
where high performance is required.

 

PIE-1 encoder makes integration with Video Managment Software less complicated
using Power over Ethernet technology and IP communication.

iconexe

Redwall Event Code integration Plug-in for AXIS
and AVIGILON

pdf_120 Brochure REDWALL IP
pdf_120

Video Management Software
integration list

pdf_120

REDWALL-V
adjustment procedures guide

vimeo_60_01

Adjustment procedures guide
- video

FEATURES
  • IP communication and Power over Ethernet power supply

    - easy integration with IP Video management Software

    - use of IP cameras infrastructure

    - Redwall Event Code communication protocol is implemented

    into major types of Video Management Software

  • Detector's configuration (PIE-1 encoder) using web browser

    - use of alarm relays

    - detector's IP address

    - type of transmission protocol - TCP or UDP

  • Intelligent PIR Detection System
    - Detection of ambient temperature and illuminance for automatic sensitivity management
    - Advanced detection algorithm
    - Three dual pyro-elements with patented Double Conductive Shielding

  • Anti-vandalism functions
    - Anti-rotation function with 3-axis accelerometer
    - Anti-masking function with photo-beam
    - Reinforced polycarbonate housing
    - Max. 4m (13ft.) installation height

  • Independent sensitivity selector for near/far areas

  • Detection logic selector

  • Detection range selector

  • Independent N.C. and N.O. outputs

    - N.C. outputs can be connected to PIE-1 encoder for IP communication

    or to dry contacts of camera / video recorder directly

  • Adjustable alarm interval time

  • PIE-1 encoder included

SYSTEM DIAGRAM

redwall-ip_en_630

DETECTION AREA

sip-3020_en_650

DIMENSIONS

They are REDWALL-V detector's dimensions only

wymiary_sip-3020

PIE-1 encoder must be installed in the waterproof box (available on the market) separately

SPECIFICATION
Model

SIP-3020-IP

SIP-4010-IP

SIP-404-IP

Detection method

Passive infrared

Coverage

30 x 20 m (100 x 65 ft.)

40 x 10 m (130 x 33 ft.)

40 x 4 m (130 x 13 ft.)

Power input

Power over Ethernet (IEEE802.3af/at) using PIE-1 encoder

11-16V DC
22-26V AC
22-26V AC with optional heater (non-operated by PoE)

Current draw

35mA max. (12V DC)
70mA max. (24V AC)
410mA max. (24V AC) with optional heater (non-operated by PoE)

Mounting height

2,3 to 4 m (7,6 to 13 ft.)

Sensitivity selector

Far: SH/H/M/L

Near: SH/H/M/L

Range selector

Far: On/Off

Alarm output

Redwall Event Code communication protocol (UDP / TCP) using PIE-1 encoder
or N.O., N.C. 28V DC 0,2A max.

Alarm interval period

Off/15, 30, 60 sec.

Detection logic selector

AND / OR

Trouble output

Redwall Event Code communication protocol (UDP / TCP) using PIE-1 encoder
or N.C. 28V DC 0,2A max.

Tamper output

Redwall Event Code communication protocol (UDP / TCP) using PIE-1 encoder
or N.C. 28V DC 0,1A max.

Alarm period

Approx. 2 sec.

Warm-up period

Approx. 60 sec.

Operating temperature

-25 to +60°C, -40 to +60°C (-13 to +140°F, -40 to +140°F)
with optional heating unit supplied with 22-26V AC (non-operated by PoE)

IP rating

Main unit: IP65
Chassis: IP55

Dimensions
(H x W x D)

(without market available PIE-1 mounting box)

227 x 102 x 266 mm (9.0 x 4.0 x 10.5 in.)

Weight

1,2kg

PIE-1 encoder (without mounting box): 270 g (including all accessories); Body: 90 g

PIE-1 encoder Supported protocols

IPv4, ARP, UDP, TCP, ICMP, HTTP

Function setting

Use web browser

OPTIONS
AVF-1

Area view finder
for visualization
of detection area.

SIP-HU
Heating unit for low temperature condition.

When the SIP-HU is used, the power for SIP series should be 22-26VAC.

SIP-AT
SIP Adjustment Tools

Includes AWT-3, AVF-1
and area plates for all SIP detectors

SIP-MINIHOOD
Sun/Snow shields are available.

for SIP-3020 / 4010 / 404 / 3020/5 / 4010/5 / 404/5 / 3020WF / 4010WF / 404WF

AWT-3
(walk tester)

Audible walk-tester.
Converts amplifier signals into sweeping sound
and simplifies detection area setting.

Copyright © OPTEX Security Sp. z o.o. All Rights Reserved. Realization: MEETMEDIA